NEW QUESTION # 192
What are two requirements for using the iDRACS Quick Sync feature? (Choose two.)
- A. Bluetooth connectivity
- B. Type A/A USB cable
- C. NFC enabled mobile device
- D. OpenManage Mobile app
Answer: C,D
NEW QUESTION # 193
A technician accesses the iDRAC to set up scheduled updates. This option is not available on one server, but is available on the other servers. The servers are the same model and have the same iDRAC firmware revisions.
What is required so that the technician can enable scheduled updates on the server?
- A. iDRAC reset using racadm racreset command
- B. LC Settings in Lifecycle Controller set up correctly
- C. Update option enabled in Lifecycle Controller interface
- D. iDRAC license at the Enterprise level
Answer: D
NEW QUESTION # 194
A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU.
Which redundancy options does this configuration supply?
- A. PSU redundancy and Grid redundancy
- B. No redundancy unless each PSU is connected to a separate PDU
- C. PSU redundancy only
- D. PSU redundancy and PDU redundancy
Answer: C
NEW QUESTION # 195
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in Memory mode.
What is the minimum size DIMM supported for this type of memory?
- A. 64 GB
- B. 128 GB
- C. 512 GB
- D. 256 GB
Answer: B
NEW QUESTION # 196
A technician deploy a new server in a datacenter and must install Microsoft Windows Server 2012 R2.
Which two steps are required to install the OS using the Lifecycle Controller? (Choose two.)
- A. Disable iDRAC virtual media
- B. Restore server profile
- C. Configure storage
- D. Place OS media in DVD attached to server
- E. Configure Lifecycle Controller network settings
Answer: C,D
NEW QUESTION # 197
What is the minimum number of components, beside the system board, required to POST?
- A. 1 PSU, 1 DIMM, and 1 CPU only
- B. 1 PSU and 1 CPU only
- C. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
- D. PSUs, CPUs, and DIMMs as configured in BIOS
Answer: A
NEW QUESTION # 198
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers.
Each server has the following configuration:
- 2x CPUs
- 384 GB RAM
- 6x 1TB drives in a RAID 6 virtual disk
- No hot spare drive
- PERC
- vFlash
- iDRAC9 Express license
At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then.
What is the reason for this issue not being reported to OME?
- A. Remote servers are not configured with OME as the trap destination address. OME discovered the issue during a routing status check which is configured to run at 5 PM every Friday.
- B. Remote servers need to have the iDRAC Enterprise license installed to be able to send alerts.
- C. Remote servers are not configured with OME as the trap destination address. OME was informed of the issue when remote servers sent alerts at 5 PM Friday.
- D. OME only updates its alert database at 5 PM every Friday.
Answer: A
NEW QUESTION # 199
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?
- A. IDSDM card
- B. Internal USB flash
- C. BOSS
- D. Front control panel
Answer: D
NEW QUESTION # 200
A Dell EMC PowerEdge 14G server fails to boot, and the server administrator is investigating the cause of the failure. The following event appears in the Lifecycle Log: "The Boot Guard detected a corrupted BIOS in the server".
What caused the boot failure?
- A. Incorrect BIOS
- B. Boot Guard
- C. Server compromised
- D. Motherboard faulty
Answer: B
NEW QUESTION # 201
A technician wants to obtain the highest overall efficiency from the power supplies.
Which options should the technician use?
- A. Power factor correction
Power supply hot spare - B. Power supply hot spare
A low-line power source - C. A low-line power source
Power factor correction - D. Power supply hot spare
Power supply redundancy
Answer: A
NEW QUESTION # 202
A company needs a server that meets these requirements:
- Support workloads that are accelerated and computational-heavy
- Has cyber resilient architecture and Root of Trust
- Supports HPR fans
- Supports OCP 3.0 technology
Which Dell PowerEdge server model meets these requirements?
- A. XE9680
- B. R960
- C. MX760c
Answer: A
NEW QUESTION # 203
The OS and iDRAC report 120 GB of RAM. The technician has very little time to troubleshoot the issue and cannot run diagnostics.
They are working with the following information:
- Memory mode is Optimizer
- 8x 16 GB DIMMs installed
- 2 CPUs
- No entries in the SEL in the iDRAC
- No errors in the OS
To troubleshoot this issue, what action should the technician take prior to monitoring POST for any resulting errors?
- A. Reseat all memory modules
- B. Modify server profile for Performance
- C. Add an additional memory module
- D. Change memory mode to Advanced ECC
Answer: A
NEW QUESTION # 204
A technician needs to remotely update the iDRAC with Lifecycle Controller firmware.
Which three steps should the technician take to complete the update? (Choose three.)
- A. Go to the Firmware Update page and upload the iDRAC firmware.
- B. Connect to the iDRAC GUI
- C. After firmware update completes, restart server
- D. Boot the server into F10 to start the firmware update
- E. Locate the latest iDRAC firmware and download to management station
- F. Go to Summary Page and reset the iDRAC
Answer: A,C,D
NEW QUESTION # 205
What can a technician do to ensure that no malicious code can be introduced into any of the servers through physical access?
- A. Set UEFI Variable Acces to disabled
- B. Set Secure Boot Policy to enabled
- C. Set USB 3.0 to disabled
- D. Set User Accessible Ports to disabled
Answer: D
NEW QUESTION # 206
A technician is working on an operational PowerEdge R640 server that cannot be rebooted.
Observing that all drives are hot-swappable devices, the technician decides to remove a drive that has been giving intermittent errors. After the single drive is removed the operating system crashes.
What could have caused the operating system to crash?
- A. System Lockdown mode was enabled, which does not allow any component to be hot-swapped
- B. Drive was part of a RAID 0 virtual disk
- C. PERC was configured to allow a single drive removal
- D. iDRAC was not configured for hot-swappable components
Answer: B
NEW QUESTION # 207
What does OBPAR allow on a PowerEdge MX750c?
- A. Boot a compute sled with reduced frequency.
- B. Run a compute sled with maximum performance.
- C. Boot a compute sled with only one CPU.
- D. Run a compute sled with memory overclocking.
Answer: A
NEW QUESTION # 208
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A. SupportAssist Enterprise
- B. iDRAC9
- C. OpenManage Essentials
- D. iSM
Answer: C
NEW QUESTION # 209
Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?
- A. 6x2 5" drives
- B. 8x2 5" drives
- C. 4x 3.5" drives
- D. 2x3.5" drives
Answer: D
NEW QUESTION # 210
Which processor configuration is used by the Dell EMC PowerEdge R6525 server?
- A. 2 socket Intel
- B. 4 socket Intel
- C. 2 socket AMD
- D. 4 socket AMD
Answer: C
NEW QUESTION # 211
How can a technician know whether IDRAC9 System Lockdown mode is enabled?
- A. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
- B. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
- C. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
- D. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
Answer: A
NEW QUESTION # 212
......